Sukup Grain Dryer Resources

Looking for a refresher or tutorial for your Sukup grain dryer?  Check out our collection of resources to keep yourself informed and current with the latest information on how to get the most of the equipment you have purchased from the team at Devolder Farms



Operating Your Sukup Grain Dryer


QuadraTouch Software


QuadraTouch Troubleshooting


Grain Dryer Faults


Tower Dryer Faults


Drying Rates Charts

ALWAYS OBSERVE SAFE OPERATING PRACTICES!  If a dryer or bin must be entered for maintenance; isolate and disengage energy sources and follow all applicable safety regulations.  Manuals and safety guides are available for reference on manufacturer’s site.

Operating Your Sukup Grain Dryer


Grain Dryer Startup Webinar

Best Way To Run Your Sukup Dryer

Best Way To Run Your Mixed Flow Dryer

Moisture Sensor Accuracy Tips

QuadraTouch Software


Downloading QuadraTouch Pro Software

Installing QuadraTouch Pro Software

Re Imaging A QuadraTouch Pro HMI

Assigning An IP Address To A PLC

Downloading QuadraTouch Classic Software

Installing QuadraTouch Classic Software

Downloading QuadraTouch Classic Software

Communication Error For QuadraTouch Classic

QuadraTouch Troubleshooting


PLC Lights Explanation

How To Change A PLC Card

Fixing A PLC Fail Light

Calibrating An Electronic Mod Valve

Troubleshooting No Flame Fault

Troubleshooting 24VDC Short

Troubleshooting Strange I / O

Explain The MUX Fault

Programming An ATV320 VFD

Programming AN ATS22 Soft Start

Auxiliary Power Box Wiring

Grain Dryer Faults


Air Switch Sensor

Grain Fill Paddle Switch

Meter Roll Proximity Switch

Unload Auger Proximity Switch

Heater Housing Overtemp Switch

Grain Column Overtemp Sensor

Plenum Overtemp Sensor

Vapour Overtemp Sensor

Discharge Moisture Sensor

Flame Sensor Fault

Plenum RTD Fault

Motor Overload Protection

Rear Door Fault #36

Rear Discharge Chute Fault #42

Soft Start Fault

User Fault

How The Power Is Distributed From The Power Box

Tower Dryer Faults


Access Door Fault #36

Air Switch No Pressure Detected Fault #143, 243, 343 and 443

Flame Not Detected Fault #45

Soft Start Fail Fault #1, 2, 3 and 4

Upper Column Overtemp Sensor Fault #84 Left or 85 Right

Middle Column Overtemp Fault #82 Left or 83 Right

Lower Column Overtemp Fault #80 and 81

Plenum Overtemp Fault #39

Vapour Overtemp Fault #37

Burner Unit Failure Fault #38

Motor Overload Fault #49

Troubleshooting The Paddle Switch Wiring

Grain Drying Rates Instructional Charts

Drying Rates Instructional Charts
Cross Flow Dryer
Mixed Flow Dryer
Tower Dryer
Drying Rates Instructional Charts

Select the applicable dryer style tab to locate the specific grain drying chart for your Sukup grain dryer

Cross Flow Dryer

 

Mixed Flow Dryer

Be sure to print the right chart for the dryer. 
    -EXNO means a non-expandable dryer
    -EXYS means a 4-tier expandable dryer
    -EXDB means a 8-tier expandable dryer

Tower Dryer